The location of ground faults in underground cables can be found by

(A) Megger

(B) Murray loop test

(C) Electro-dynamometer

(D) Ohm-meter

Answer: (B) Murray loop test


Explanation:

Murray loop test:

It is the common method to determine location of earth or short circuit fault in underground cable.

It operates on the principle of the Wheatstone bridge.


The material commonly used for insulation in high voltage cables is

(A) Teflon

(B) impregnated paper

(C) rubber

(D) PVC


Answer: (B) impregnated paper


Explanation:

Generally, insulation of cables is required to have high dielectric strength, to provide the necessary withstand against normal operating and impulse voltages.

There are mainly two types of cable insulating materials.

  1. Impregnated Paper
  2. Polymer.


Impregnated paper is the most popular insulating material, especially for the land installations in the H.V and EHV lines.

Polymer insulation is preferably used in new installations like DC and the submarine system.

Around 83% of HV cables are paper insulated.

Solid paper insulated cables are suitable for application up to the MV range. At higher voltage, there is some operation problem with them due to high dielectric losses and pressure of voids.

In oil-filled cables at high voltage, the formation of voids is prevented by maintaining a flow of oil under pressure.

The impregnation of paper improves the dielectric properties of paper insulation.

Polymer insulation is immune to thermal degradation and must not be prone to defects such as voids, protrusions, or contaminants.

For extra-high voltage (400 kV and higher) new types of types mode up of PPLP (Poly propylite laminated paper) are used.

PPLP has the advantage of combining the technical traditional technology used for impregnated paper cables with the excellent electrical and dielectric properties of synthetic insulators.


More MCQS 

1. Under over excitation synchronous phase modifier works as

2. The neutral of the power system may be connected to earth

3. The time to open the circuit breaker contact is called as

4. A 100 Ah capacity battery should deliver a current of 10 A for approximately _____ hrs.

5. For 400KV line, The Spacing Between phase conductor is around 

6. Shunt capacitors in a sub-station

7. An alternator is said to be over excited when it is operating at

8. In case of transformer Buchholz relay is used to protect from 

9. Series capacitors are used to

10. Disadvantage of low power factor is

11. The colour of neutral three core flexible cable is

12. The location of ground faults in underground cables can be found by

13. Fault location in an HV cable is done by

14. The insulation resistance of a cable of length 10 km is 1 MΩ. its resistance for 50 km length will be

15. Which of the following is not a valid advantage of bundle conductor?

16. Star-star power transformer is protected by current transformer having

17. The surge resistance of cables is

18. Skin effect is only noticeable at _______ frequencies. 

19. When transmission voltage is increased, the line losses are

20. Var compensators are used to